Model NO.
BT-2P40A&BT-2Q40A
Transport Package
Wooden Case
Specification
560*450*270mm
Trademark
BOOSTEL
Origin
China
Production Capacity
2000 Set/Year

Product Description

Specifications of GSM850&DCS1800 Out of Band Frequency Shift Repeater
Model: BT-2P40A&BT-2Q40A
The Frequency Shift Repeater (FSR) is designed to solve problems of weak mobile signal, which can expand more coverage than RF repeater and reduce investment for the areas where fiber optic or dedicated cable is not allowed.
The system consists of two parts: Donor Unit and Remote Unit. The Donor Unit receives the BTS (Base Transceiver Station) signal via open air RF transmission or direct coupler closed to BTS, then converts it from the working frequency to the link frequency, and transmits the amplified signal to the Remote Unit that will reconvert the signal to the working frequency and provide the signal to the areas where network coverage is inadequate. And the mobile signal is also amplified and retransmitted to the BTS via the opposite direction.
As per operator's requirement for link frequency, two types of FSR are available:
  • In-Band FSR: the link frequency is inside the working band
  • Out-of-Band FSR: the link frequency is out of the working band
GSM 850MHz &Dcs 1800MHz out of Band Frequency Shift Repeater


 

Features

  
 
Aluminum-alloy casing with IP65 protection has high resistance to dust, water and corroding
No interference to BTS by adopting linear amplifier with high gain and low noise
Adopting filter with highly selectivity and low insertion loss eliminates interference between uplink and downlink
USB port provides a link to a notebook for local supervision or to the built-in wireless modem to communicate with the NMS (Network Management System) that can remotely supervise repeater's working status and download operational parameters to the repeater

Applications

 To expand signal coverage or fill signal blind area where  signal is weak or unavailable.
Outdoor: Airports, tourism regions, golf courses, tunnels, factories, mining districts, villages, …
Indoor: Hotels, exhibition centers, basements, shopping malls, offices, parking lots, …
 

Application Diagram

 
GSM 850MHz &Dcs 1800MHz out of Band Frequency Shift Repeater

 

Technical Specifications

Item Donor Unit Remote Unit
GSM850/ DCS1800 GSM850/ DCS1800
Working Frequency
(Customized)
Uplink 819~849 MHz/1710~1790MHz 819~849 MHz/1710~1790MHz
Downlink 864~894 MHz/1805~1885MHz 864~894 MHz/1805~1885MHz
Link Frequency (customized) 1.5G
Max. Input Power (Non-Destructive) 10dBm
Transmission Distance ≤ 20km
Frequency Error ≤ 0.05ppm
In-band Ripple ≤ 3dB
Maximum Output Power(Customized) Uplink 40dBm 40dBm
Downlink 40dBm 40dBm
Maximum Gain ≥ 90dB 90dB
Gain Adjustment Range 1~31 dB @ step of 1 dB
Voltage Standing Wave Ratio < 1.5
Noise Figure ≤ 5dB(only for uplink)
Spurious Emission Within working band ≤ -15dBm/30kHz
Out of working band
(f > 2.5MHz)
9kHz~1GHz: ≤ -36dBm/30kHz
1GHz~12.75GHz: ≤ -30dBm/30kHz
Third-order Inter-modulation ≤ -45dBc / 30kHz (measured under rated output power)
System Delay ≤ 10μSec
I/O Impedance 50Ω
RF Connector N-Type (Female)
Temperature Range Operation: -25°C ~ + 55°C / Storage: -30°C ~ +60°C
Relative Humidity Range ≤ 95% (non condensing)
Power Supply (customized) DC-48V or AC110V or AC220V,50/60Hz
Power consumption ≤ 200W ≤ 200W
Backup Power Supply (optional) 4 hours
Casing Level IP65
Dimensions 500*440*235mm
Weight 50kg 50kg
NMS Monitoring Function (optional) Real-time alarm for door status, temperature, power supply, LNA, VSWR, self-oscillation, etc;
Remote control such as turn on/off, increasing/decreasing output power, changing channel frequency, etc;
Real-time status for output/input power, all status of repeater etc.
 
Installation & Commissioning

1.1 Installation

1.1.1 Steps for mounting on the Pole

 
  1. At Donor site, install the FSR Donor Unit, Donor Antenna, Link Antenna, and RF cable as per specified plan and site layout. FSR Donor Unit can be pole-mounted using the brackets as shown below.
  2. Place M8 screws through the holes of H type brackets as shown in figure 1
  3. Fix combiner onto the H type brackets with M6 screws
  4. Fix H type brackets with combiner installed onto the pole with U type brackets and M8 screws
GSM 850MHz &Dcs 1800MHz out of Band Frequency Shift Repeater
 
 
Figure 1 Repeater Mounting Bracket
 
  1. Orient the Link Antenna of Donor Site to the direction of the Remote Site.
  2. Use Site Master to measure the VSWR of the RF cable from the Link Antenna. The value should be less than 1.5; Otherwise, check the connectors and the installation of the cable.
  3. Start Commissioning the Donor Unit .
  4. Proceed to the Remote Site.
  5. At Remote site, install the FSR Remote Unit, Link Antenna, Coverage Antenna, and RF cables. Remote Unit can be wall mounted or pole mounted depending on the approved plan.
  6. Orient the Remote Link Antenna to the direction of the Donor Site.
  7. Using Spectrum Analyzer, check the Link RSL; adjust the Link Antennas of both Donor and Remote until the required RSL is achieved. Link RSL can be computed using conventional path calculation method.
  8. Then, measure the VSWR of the RF cables connecting with the Link Antenna of Remote Unit. The value should be less than 1.5, otherwise, check the connectors and the installation of the cable.
  9. Start Commissioning the Remote Unit .

1.1.2 Steps for mounting on the wall

 
  1. At Donor site, install the FSR Donor Unit, Donor Antenna, Link Antenna, and RF cable as per specified plan and site layout. FSR Donor Unit can be wall-mounted using the brackets as shown below.
  2. Make four marks on the wall according to the dimension shown as figure 2
  3. Drill four holes at position marked
  4. Fix two pcs H type brackets on the wall with M8 expansion screws
  5. Fix combiner onto the brackets with M6 screws
 
GSM 850MHz &Dcs 1800MHz out of Band Frequency Shift Repeater

Figure 2 Repeater Mounting Bracket
     6. The following steps are the same with step 4 to 12 for mounting on the Pole.

 

 1.2 Commissioning

  1. Connect the RF cable from Donor Antenna to the spectrum analyzer and check if the Donor Antenna is receiving the correct frequency; and then measure the signal level of the said frequency (RSL). Adjust the antenna to make the readings approach the recorded value on the survey report. Record all readings.
  2. Inside the repeater, disconnect the uplink duplexer to the ICS module so as to cut any signal coming from air going to the uplink duplexer and thus protecting the amplifier from damaging. Connect a 30 dB attenuator to the output of the repeater; this attenuator will serve as a load for the repeater. The purpose of this attenuator is to protect the equipments from damaging.
  3. Turn ON the repeater. Observe the LED display on the NMS board. Check for any alarm. Under normal condition, the POWER LED should be always green and the RUN LED should be blinking, the ALARM LED should be not bright with red color.
GSM 850MHz &Dcs 1800MHz out of Band Frequency Shift Repeater

Figure3 Interface of NMS Board

 
Connect your laptop to the repeater via the data cable.
GSM 850MHz &Dcs 1800MHz out of Band Frequency Shift Repeater

Send your message to this supplier

*From:
*To:
avatar Mr. Victor
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2017

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Type of Ownership
Limited Company
Management System Certification
ISO9001:2015